Airmar 120WXH Weather Station Instrument

Airmar 120WXH Weather Station Instrument

Quantity:
 

Airmar 120WXH Weather Station Instrument

The Airmar 120WXH Weather Station has been carefully designed, with a highly effective thermostatically controlled heating system, for operation in ice-prone areas both onshore and offshore. The heater element is designed to keep the wind channel free of snow and ice.
  • Ultrasonic wind readings
  • Thermostatically controlled heater element
  • Apparent Wind speed & angle
  • Barometric pressure
  • Air temperature
  • Wind chill
  • IPX6 Ingres protection
  • Output: Via a single cable (various lengths available)
  • NMEA 0183 protocol over RS-422 standard interface OR RS232 interface
  • NOTE: The 120WXH CANNOT be used with an NMEA 2000® CAN BUS network

Wind Data

  • Wind Speed Range:
  • 0 knots to 78 knots (0 MPH to 90 MPH, 0 m/s to 40 m/s)
  • Wind Speed Resolution:
  • 0.1 knot (0.1 MPH, 0.1 m/s)
  • Wind Speed Accuracy @ 0°C to 55°C (32°F to 131°F), no precipitation*:
  • Low Wind Speeds:
  • 0 -10knots; 1knot RMS +10% of reading
  • (0 MPH to 11.5 MPH; 1.1MPH +10% of reading)
  • (0 m/s to 5 m/s; 0.5 m/s +10% of reading)
  • High Wind Speeds:
  • 10-78 knots; 2 knots RMS or 5%, whichever is greater
  • (11.5 MPH to 90 MPH; 2.3 MPH or 5%, whichever is greater)
  • (5 m/s to 40 m/s; 1 m/s or 5%, which ever is greater)
  • Wind Speed Accuracy in wet conditions**:
  • 5 knots RMS (5.7 MPH RMS, 2.5 m/s RMS)
  • Wind Direction Range: 0° to 360°
  • Wind Direction Resolution: 0.1°
  • Wind Direction Accuracy @ 0°C to 55°C (32°F to 131°F), no precipitation*:
  • Low Wind Speeds (5° RMS typical):
  • 4 - 10 knots (4.6 MPH to 11.5 MPH, 2 m/s to 5 m/s)
  • High Wind Speeds (2° RMS typical):
  • >10 knots (>11.5 MPH, >5 m/s)
  • Wind Direction Accuracy in wet conditions** (8° RMS Typical):
  • 8 knots (>9.2 MPH, >4 m/s)

Pitch and Roll Data

  • Pitch and Roll Range / Accuracy: ±50° / <1°

Air Temperature Data

  • Air Temperature Range***: -40°C to 55°C (-40°F to 131°F)
  • Air Temperature Resolution: 0.1°C (0.1°F)
  • Air Temperature Accuracy: ±1.1°C (±2°F)* @ >4 knots wind (>4.6 MPH wind) (>2 m/s wind)

Barometric Pressure Data

  • Barometric Pressure Range: 300 mbar to 1100 mbar (24 inHg to 33 inHg, 800 hPa to 1100 hPa)
  • Barometric Pressure Resolution: 0.1 mbar (0.029 inHg, 0.1 hPa)
  • Barometric Pressure Accuracy: ±1 mbar (±0.029 inHg, ±1 hPa) when altitude correction is available

Operating Temperature

  • Operating Temperature Range: -25°C to 55°C (-13°F to 131°F)
  • Heater Operating Temperature Range: -40°C to 55°C
  • Heater cycles when sensor reaches 1°C

Supply Voltage

  • Supply Voltage: 12 VDC to 24 VDC
  • Heater Supply Voltage: 24 VDC
  • Supply Current (@ 24 VDC):
  • <.1.0W (<42mA)
  • Heater Supply Current (@ 24 VDC):
  • <.60W (2.5A)

Data Input/Output

  • Output: Via a single cable (various lengths available)
  • NMEA 0183 protocol over RS-422 standard interface OR RS232 interface
  • NOTE: The 120WXH CANNOT be used with an NMEA 2000® CAN BUS network

Other Specifications for the Airmar 120WXH Weather Station

  • Weight: 300 grams (0.8 lb)
  • Communication Interface: NMEA 0183 (RS232 or RS-422 standard & CAN)
  • Mounting Thread Size on Base: Standard 1”-14 UNS (3/4” NPT optional)
  • Certifications and Standards: CE, IPX6, RoHS, IEC61000-4-2, IEC60945
RMS—Root Mean Square, LEN—Load Equivalency Number *When the wind speed is less than 2 m/s (4.6 MPH) and/or air temperature is below 0°C (32°F), wind, temperature, and relative humidity readings will be less accurate. **Wet conditions include moisture, rain, frost, dew, snow, ice and/or sea spray in the wind channel. ***Temperature results invalid during heater operation

FOR FURTHER ASSISTANCE

Customer service

We are available from monday to friday to answer your questions.